Proceedings of the 10th Convention of the European Acoustics Association Forum Acusticum 2023 Politecnico di Torino Torino, Italy September 11 - 15, 2023 |
|
Abstract For predictions of the sound transmission from installations in buildings using EN 12354 the normalised impact sound pressure level of floors and walls is required. An alternative to the ISO tapping machine, such as an electrodynamic tapping machine or a mechanical pendulum tapping machine, would be beneficial to directly measure on walls, but is not available for purchase. Therefore, the indirect measurement of the wall impact sound pressure level via transfer functions was investigated. Transfer functions were measured according to EN 10848 and the blocked force of the ISO tapping machine is used as an input. The two alternative tapping machines were characterised on a reception plate according to EN 15657, along with ISO tapping machines, showing a good agreement of the blocked force. Hence, they are generally suitable for the direct measurement. Measurements in testing facilities conforming to EN ISO 10140 were performed to validate the indirect method. The results showed that the method with the transfer functions works well in the building acoustics frequency range, when compared with the direct measurement. Accordingly, this method is proposed in prEN 17823 for the laboratory measurement of the impact sound insulation of stairs and stair isolating elements. |
||||||||||||||||||||