Proceedings of the 11th Convention of the European Acoustics Association Forum Acusticum / EuroNoise 2025 Málaga, Spain June 23 - 26, 2025 |
|
Abstract Ultrasonic imaging based on beamforming relies generally on the precise synchronization of signals within a sensor network. Time shifts in these signals—often caused by sensor clock drifts—can be estimated and corrected during post-processing, prior to applying the back␂propagation algorithm, using methods like the Peak Correlation Technique (PCT). However, in certain situations, particularly when defects exhibit anisotropy effects, additional time shifts can distort the backpropagated signals, undermining the accuracy of defect localization. This study focuses on statistically quantifying the impact of anisotropy-induced time shifts the contrast of defect localization images. The analysis is conducted in a thin reverberating plate, where covariance matrices are recorded in Full Matrix Capture (FMC) mode under two conditions: with and without a defect. Numerical simulations using A0 Lamb mode propagation are performed to validate the theoretical predictions. |
||||||||||||||||||||