Issue
Acta Acustica Volume 100, Issue Number 3, 2014
Number of page(s)6
DOIhttps://doi.org/10.3813/AAA.918737
 
 
 
Measure Low Level and High Frequency Ultrasonic Power by Self-Reciprocity Technique
 
 
  • Guangzhen Xing
  • Ping Yang
  • Wende Shou
 
 
Abstract
Radiation force balance (RFB) method, a widely accepted method to measure ultrasonic power, suffers poor performance at low level power (<10 mW) and high frequency range (>15 MHz) because of the medium attenuation, thermal drift and target imperfections. In this article, considering the diffraction and attenuation effects, we derived the power formula for both plan piston transducers and focusing transducers based on reciprocity theorem, turned power measurement to the measurement of first reflected echo voltage and short-circuit current. The diffraction effect for focusing transducers was evaluated using numerical computation of the Rayleigh integral. One way to estimate the reflection coefficient of focusing beams on heterogeneous interface was also depicted. The sensitivity can be improved and the high frequency ultrasonic power is extended to 0.1 mW and 25 MHz. Comparison experiment with RFB method illustrates that ultrasonic power measurement by self-reciprocity technique is sound in theory and feasible in practice, and can be extended to high frequency ultrasound measurement.