Determination of Vibration Reduction Indices Using Wave Theory for Junctions in Heavyweight Buildings
C. Hopkins
Abstract
Airborne and impact sound insulation in buildings can be predicted according to the International Standard, ISO 15712 and the identical European Standard, EN 12354. Calculation of the flanking transmission requires knowledge of the vibration reduction index for which these standards
contain empirical data. This paper investigates the vibration reduction index for the specific case of heavyweight buildings built from solid masonry/concrete walls and floors by using wave theory to calculate data for L-, T- and X-junctions. Calculations are carried out assuming only bending
wave transmission at the junction as well as bending and in-plane wave transmission at the junction. The results show that the frequency-invariant empirical data in the standards is likely to give rise to errors in the mid- and high-frequency ranges due to the importance of in-plane wave generation
at the junction. Regression analysis is used to identify new relationships that are specific to junctions of solid heavyweight walls and floors. For future work these give the potential to re-assess the existence of any bias error using the model in the standards and allow greater insight
into the uncertainty associated with the model.