Issue
Acta Acustica Volume 101, Issue Number 4, 2015
Number of page(s)8
DOIhttps://doi.org/10.3813/AAA.918868
 
 
 
Impulsive Noise Detection in Sweep Measurements
 
 
  • M. Guski
  • M. Vorländer
 
 
Abstract
Sweeps used as excitation signals for impulse response measurements show various advantages compared to other excitation signals regarding time variances, non-linearities and signal to noise ratio. The main disadvantage of sweeps is the sensitivity to impulsive noise during the measurement, because the noise affects specific frequencies with rather high noise levels. The fact that the occurrence of impulsive noise is hard to detect complicates the problem. Maximum length sequence or similar techniques, where the signal excites all frequencies (pseudo-)randomly, are more robust against impulsive noise, because any kind of background noise is spread over the full time range of the impulse response with relatively low levels. In this paper a detection method for impulsive noise in sweep measurements is presented. The excitation signal is removed from the recorded signal to obtain an estimation of the background noise during the measurement. In this processed signal the impulsive noise is clearly visible against the stationary background noise. After the measurement, this detection can be automatically executed and allows a repetition of measurement, if necessary.