Issue
Acta Acustica Volume 97, Issue Number 5, 2011
Number of page(s)6
DOIhttps://doi.org/10.3813/AAA.918452
 
 
 
Imaging Cracks in Bones Using Acoustic Nonlinearity: A Simulation Study
 
 
  • Yang Liu
  • Xiasheng Guo
  • Zhao Da
  • Dong Zhang
  • Xiufen Gong
 
 
Abstract
This article proposes an acoustic nonlinear approach combined with the time reversal technique to image cracks in long bones. In this method, the scattered ultrasound generated from the crack is recorded, and the third harmonic nonlinear component of the ultrasonic signal is used to reconstruct an image of the crack by the time reversal process. Numerical simulations are performed to examine the validity of this approach. The fatigue long bone is modeled as a hollow cylinder with a crack of 1, 0.1, and 0.225 mm in axial, radial and circumferential directions respectively. A broadband 500 kHz ultrasonic signal is used as the exciting signal, and the extended three-dimensional Preisach-Mayergoyz model is used to describe the nonclassical nonlinear dynamics of the crack. Time reversal is carried out by using the filtered third harmonic component. The localization capability depends on the radial depth of the crack.