Proceedings of the 11th Convention of the European Acoustics Association Forum Acusticum / EuroNoise 2025 Málaga, Spain June 23 - 26, 2025 |
|
Abstract ASTM E795-23 specifies a Type J mounting WITHOUT A SURROUND for the measurement of the sound absorption of sound absorption units and requires that the measured sound absorption be reported. ISO 354:2003(E) specifies a Type J mounting WITH A SURROUND for the measurement of the sound absorption per unit of rectangular unit sound absorber pads or baffles. ISO 354:2003(E) also says that for a specified array of objects, the result is given as the sound absorption coefficient, and that in the case of a test specimen WITH A SURROUND, it is the area enclosed by the surround that is used. However, ISO 354:2003(E) also allows an array of objects to be measured WITHOUT A SURROUND and requires the sound absorption coefficient to be reported using the area covered by the test specimen. A baffle array could be regarded as being in a Type A mounting without covered edges. ISO 354:2003(E) says that if the edges are not covered, the area of the edges shall be included in calculating the test specimen area. Consultants want sound absorption coefficients that they can enter their ray tracing programs. The existence of five different ways of measuring and/or reporting sound absorption is unacceptable. |
||||||||||||||||||||